Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.632
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(5): 1050-1054, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38501328

RESUMO

INTRODUCTION: Tricuspid regurgitation is associated with significant morbidity and mortality, and occurs at a higher rate in patients with cardiovascular implantable electronic devices. Percutaneous strategies for managing tricuspid regurgitation are evolving, including the development of bicaval valve implantation which has been successfully used in patients with pacing leads. METHODS AND RESULTS: We present the first documented case of lead failure following TricValve® implantation, a dedicated self-expanding system for bicaval valve implantation, and the first successful lead revision procedure in this setting. CONCLUSION: The case illustrates important considerations in undertaking percutaneous intervention in patients with cardiovascular implantable electronic devices, and their ongoing management.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Masculino , Idoso , Resultado do Tratamento , Reoperação , Desenho de Prótese , Remoção de Dispositivo , Feminino , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos
3.
Europace ; 25(10)2023 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-37766466

RESUMO

AIMS: This study aimed to investigate the impact of cardiac resynchronization therapy with a defibrillator (CRT-D) on mortality, comparing it with CRT with a pacemaker (CRT-P). Additionally, the study sought to identify subgroups, evaluate the time trend in treatment effects, and analyze patient characteristics, considering the changing indications over the past decades. METHODS AND RESULTS: PubMed, CENTRAL, and Embase up to October 2021 were screened for studies comparing CRT-P and CRT-D, focusing on mortality. Altogether 26 observational studies were selected comprising 128 030 CRT patients, including 55 469 with CRT-P and 72 561 with CRT-D device. Cardiac resynchronization therapy with defibrillator was able to reduce all-cause mortality by almost 20% over CRT-P [adjusted hazard ratio (HR): 0.85; 95% confidence interval (CI): 0.76-0.94; P < 0.01] even in propensity-matched studies (HR: 0.83; 95% CI: 0.80-0.87; P < 0.001) but not in those with non-ischaemic aetiology (HR: 0.95; 95% CI: 0.79-1.15; P = 0.19) or over 75 years (HR: 1.08; 95% CI 0.96-1.21; P = 0.17). When treatment effect on mortality was investigated by the median year of inclusion, there was a difference between studies released before 2015 and those thereafter. Time-trend effects could be also observed in patients' characteristics: CRT-P candidates were getting older and the prevalence of ischaemic aetiology was increasing over time. CONCLUSION: The results of this systematic review of observational studies, mostly retrospective with meta-analysis, suggest that patients with CRT-D had a lower risk of mortality compared with CRT-P. However, subgroups could be identified, where CRT-D was not superior such as non-ischaemic and older patients. An improved treatment effect of CRT-D on mortality could be observed between the early and late studies partly related to the changed characteristics of CRT candidates.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Humanos , Terapia de Ressincronização Cardíaca/métodos , Cardioversão Elétrica/instrumentação , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Fatores de Tempo , Dispositivos de Terapia de Ressincronização Cardíaca
5.
Eur Heart J ; 44(3): 180-192, 2023 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-36285872

RESUMO

AIMS: To evaluate the association of basic life support with survival after sports-related sudden cardiac arrest (SR-SCA). METHODS AND RESULTS: In this systematic review and meta-analysis, a search of several databases from each database inception to 31 July 2021 without language restrictions was conducted. Studies were considered eligible if they evaluated one of three scenarios in patients with SR-SCA: (i) bystander presence, (ii) bystander cardiopulmonary resuscitation (CPR), or (iii) bystander automated external defibrillator (AED) use and provided information on survival. Risk of bias was evaluated using Risk of Bias in Non-randomized Studies of Interventions. The primary outcome was survival at the longest follow up. The meta-analysis was conducted using the random-effects model. The Grading of Recommendations Assessment, Development, and Evaluations (GRADE) approach was used to rate certainty in the evidence. In total, 28 non-randomized studies were included. The meta-analysis showed significant benefit on survival in all three groups: bystander presence [odds ratio (OR) 2.55, 95% confidence interval (CI) 1.48-4.37; I2 = 25%; 9 studies-988 patients], bystander CPR (OR 3.84, 95% CI 2.36-6.25; I2 = 54%; 23 studies-2523 patients), and bystander AED use (OR 5.25, 95% CI 3.58-7.70; I2 = 16%; 19 studies-1227 patients). The GRADE certainty of evidence was judged to be moderate. CONCLUSION: In patients with SR-SCA, bystander presence, bystander CPR, and bystander AED use were significantly associated with survival. These results highlight the importance of witness intervention and encourage countries to develop their first aid training policy and AED installation in sport settings.


Assuntos
Reanimação Cardiopulmonar , Morte Súbita Cardíaca , Cardioversão Elétrica , Serviços Médicos de Emergência , Parada Cardíaca Extra-Hospitalar , Humanos , Reanimação Cardiopulmonar/métodos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Serviços Médicos de Emergência/métodos , Parada Cardíaca Extra-Hospitalar/terapia
6.
N Engl J Med ; 387(21): 1947-1956, 2022 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-36342151

RESUMO

BACKGROUND: Despite advances in defibrillation technology, shock-refractory ventricular fibrillation remains common during out-of-hospital cardiac arrest. Double sequential external defibrillation (DSED; rapid sequential shocks from two defibrillators) and vector-change (VC) defibrillation (switching defibrillation pads to an anterior-posterior position) have been proposed as defibrillation strategies to improve outcomes in patients with refractory ventricular fibrillation. METHODS: We conducted a cluster-randomized trial with crossover among six Canadian paramedic services to evaluate DSED and VC defibrillation as compared with standard defibrillation in adult patients with refractory ventricular fibrillation during out-of-hospital cardiac arrest. Patients were treated with one of these three techniques according to the strategy that was randomly assigned to the paramedic service. The primary outcome was survival to hospital discharge. Secondary outcomes included termination of ventricular fibrillation, return of spontaneous circulation, and a good neurologic outcome, defined as a modified Rankin scale score of 2 or lower (indicating no symptoms to slight disability) at hospital discharge. RESULTS: A total of 405 patients were enrolled before the data and safety monitoring board stopped the trial because of the coronavirus disease 2019 pandemic. A total of 136 patients (33.6%) were assigned to receive standard defibrillation, 144 (35.6%) to receive VC defibrillation, and 125 (30.9%) to receive DSED. Survival to hospital discharge was more common in the DSED group than in the standard group (30.4% vs. 13.3%; relative risk, 2.21; 95% confidence interval [CI], 1.33 to 3.67) and more common in the VC group than in the standard group (21.7% vs. 13.3%; relative risk, 1.71; 95% CI, 1.01 to 2.88). DSED but not VC defibrillation was associated with a higher percentage of patients having a good neurologic outcome than standard defibrillation (relative risk, 2.21 [95% CI, 1.26 to 3.88] and 1.48 [95% CI, 0.81 to 2.71], respectively). CONCLUSIONS: Among patients with refractory ventricular fibrillation, survival to hospital discharge occurred more frequently among those who received DSED or VC defibrillation than among those who received standard defibrillation. (Funded by the Heart and Stroke Foundation of Canada; DOSE VF ClinicalTrials.gov number, NCT04080986.).


Assuntos
Cardioversão Elétrica , Parada Cardíaca Extra-Hospitalar , Fibrilação Ventricular , Adulto , Humanos , Canadá , Desfibriladores , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/métodos , Parada Cardíaca Extra-Hospitalar/mortalidade , Parada Cardíaca Extra-Hospitalar/terapia , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/terapia , Estudos Cross-Over , Análise por Conglomerados
8.
Circ Arrhythm Electrophysiol ; 15(2): e010557, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-35089800

RESUMO

BACKGROUND: Limited data exist regarding implantable cardioverter defibrillator (ICD) usage in infants and toddlers. This study evaluates ICD placement indications, procedural techniques, programming strategies, and outcomes of ICDs in infants and toddlers. METHODS: This is a single-center retrospective review of all patients ≤3 years old who received an ICD from 2009 to 2021. RESULTS: Fifteen patients received an ICD at an age of 1.2 years (interquartile range [IQR], 0.1-2.4; 12 [80%] women; weight, 8.2 kg [IQR, 4.2-12.6]) and were followed for a median of 4.28 years (IQR, 1.40-5.53) or 64.2 patient-years. ICDs were placed for secondary prevention in 12 patients (80%). Diagnoses included 8 long-QT syndromes (53%), 4 idiopathic ventricular tachycardias/ventricular fibrillations (VFs; 27%), 1 recurrent ventricular tachycardia with cardiomyopathy (7%), 1 VF with left ventricular noncompaction (7%), and 1 catecholaminergic polymorphic ventricular tachycardia (7%). All implants were epicardial, with a coil in the pericardial space. Intraoperative defibrillation safety testing was attempted in 11 patients (73%), with VF induced in 8 (53%). Successful restoration of sinus rhythm was achieved in all tested patients with a median of 9 (IQR, 7.3-11.3) J or 0.90 (IQR, 0.68-1.04) J/kg. Complications consisted of 1 postoperative chylothorax and 3 episodes of feeding intolerance. VF detection was programmed to 250 (IQR, 240-250) ms with first shock delivering 10 (IQR, 5-15) J or 1.1 (IQR, 0.8-1.4) J/kg. Three patients (20%) received appropriate shocks for ventricular tachycardia/VF. No patient received an inappropriate shock. There were 2 (13%) ventricular lead fractures (at 2.6 and 4.2 years post-implant), 1 (7%) pocket-site infection, and 2 (13%) generator exchanges. All patients were alive, and 1 patient (7%) received a heart transplant. CONCLUSIONS: ICDs can be safely and effectively placed for sudden death prevention in infants and toddlers with good midterm outcomes.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Fatores Etários , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Pré-Escolar , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Lactente , Masculino , Prevenção Primária , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Prevenção Secundária , Fatores de Tempo , Resultado do Tratamento
9.
Isr Med Assoc J ; 24(1): 25-32, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35077042

RESUMO

BACKGROUND: Endocardial leads of permanent pacemakers (PPM) and implantable defibrillators (ICD) across the tricuspid valve (TV) can lead to tricuspid regurgitation (TR) or can worsen existing TR with subsequent severe morbidity and mortality. OBJECTIVES: To evaluate prospectively the efficacy of intraprocedural 2-dimentional-transthoracic echocardiography (2DTTE) in reducing/preventing lead-associated TR. METHODS: We conducted a prospective randomized controlled study comparing echocardiographic results in patients undergoing de-novo PPM/ICD implantation with intraprocedural echo-guided right ventricular (RV) lead placement (Group 1, n=56) versus non-echo guided implantation (Group 2, n=55). Lead position was changed if TR grade was more than baseline in Group 1. Cohort patients underwent 2DTTE at baseline and 3 and/or 6 months after implantation. Excluded were patients with baseline TR > moderate or baseline ≥ moderate RV dysfunction. RESULTS: The study comprised 111 patients (74.14 ± 11 years of age, 58.6% male, 19% ICD, 42% active leads). In 98 patients there was at least one follow-up echo. Two patients from Group 1 (3.6%) needed intraprocedural RV electrode repositioning. Four patients (3.5%, 2 from each group, all dual chamber PPM, 3 atrial fibrillation, 2 RV pacing > 40%, none with intraprocedural reposition) had TR deterioration during 6 months follow-up. One patient from Group 2 with baseline mild-moderate aortic regurgitation (AR) had worsening TR and AR within 3 months and underwent aortic valve replacement and TV repair. CONCLUSIONS: The rate of mechanically induced lead-associated TR is low; thus, a routine intraprocedural 2DTTE does not have a significant role in reducing/preventing it.


Assuntos
Ecocardiografia/métodos , Complicações Pós-Operatórias , Ajuste de Prótese , Implantação de Prótese , Cirurgia Assistida por Computador/métodos , Insuficiência da Valva Tricúspide , Valva Tricúspide/diagnóstico por imagem , Idoso , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Feminino , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Marca-Passo Artificial , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Ajuste de Prótese/efeitos adversos , Ajuste de Prótese/métodos , Implantação de Prótese/efeitos adversos , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/diagnóstico , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/prevenção & controle
10.
In. Soeiro, Alexandre de Matos; Leal, Tatiana de Carvalho Andreucci Torres; Accorsi, Tarso Augusto Duenhas; Gualandro, Danielle Menosi; Oliveira Junior, Múcio Tavares de; Caramelli, Bruno; Kalil Filho, Roberto. Manual da residência em cardiologia / Manual residence in cardiology. Santana de Parnaíba, Manole, 2 ed; 2022. p.545-547, tab.
Monografia em Português | LILACS | ID: biblio-1352997
13.
Pacing Clin Electrophysiol ; 44(11): 1918-1924, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34523140

RESUMO

BACKGROUND: The subcutaneous cardioverter-defibrillator (S-ICD) continues to be preferentially used in relatively young patients, with less advanced heart disease. OBJECTIVE: We, therefore, studied the short and long-term efficacy and safety of the S-ICD in subgroups of patients, which are underreported at present. METHODS: A total of 218 patients between November 2010 and February 2019 undergoing S-ICD with a follow up of at least 6 months implantation were included in a prospective registry. Mean follow up was 38 months. RESULTS: The most common indication for S-ICD implantation was ischemic cardiomyopathy (n = 106, 49%). Complication rate needing invasive intervention was 9% (n = 21). Appropriate shock rate in patients with an S-ICD was 3.5%/year. A total of 30 inappropriate shocks (IAS) occurred in 19 patients (8.7%; 2.7%/year). The proportion of appropriate and inappropriate shock rates in patients with different cardiomyopathies shows remarkable variances. There were significant more IAS (3.6%/year vs. 1.7%/year, p = .048) in patients with non-ischemic cardiomyopathy versus patients with ischemic cardiomyopathy. Multivariate analysis identified, besides type of cardiomyopathy, atrial fibrillation (AF) as predictor for IAS. CONCLUSION: In this real-world prospective registry we analyzed S-ICD performance in the more traditional ICD patient. Patients with ischemic cardiomyopathy had significantly less inappropriate therapy compared to patients with non-ischemic cardiomyopathy and appear to be appropriate patients for this type of device.


Assuntos
Cardiomiopatias/fisiopatologia , Cardiomiopatias/terapia , Cardioversão Elétrica/instrumentação , Isquemia Miocárdica/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Países Baixos , Segurança do Paciente , Sistema de Registros
14.
BMC Cardiovasc Disord ; 21(1): 411, 2021 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-34454427

RESUMO

BACKGROUND: Self-reported health status as measured by the Kansas City Cardiomyopathy Questionnaire (KCCQ) in patients with primary prevention implantable cardioverter defibrillators (ICDs) has mainly been reported from randomized trials. However, these studies are often limited to short follow-up and are subject to selection bias. The aim of this study was to assess KCCQ-12 in patients with primary prevention ICD due to either ischemic or nonischemic heart failure. METHODS: This cross-sectional observational study included all patients in Region Gävleborg, Sweden, who because of primary prevention due to heart failure, had an ICD or underwent device replacement between 2007 and 2017. After validation using medical records patients were sent and returned the KCCQ-12 by regular mail. RESULTS: A total of 118 questionnaires were analyzed (response rate 71.1%). The mean age was 70.9 ± 9.8 years, and a minority was female (n = 20, 16.9%). The mean overall summary score was 71.5 ± 22.4, there was no significant difference between ischemic and nonischemic heart failure (69.5 ± 23.1 vs. 74.4 ± 21.3; p = 0.195). Atrial fibrillation at baseline was associated with lower score for the domains Symptom frequency (70.2 ± 23.2 vs. 82.2 ± 19.2; p = 0.006) and Social limitation (62.1 ± 26.0 vs. 75.6 ± 26.6; p = 0.006) as well as the overall summary score (63.9 ± 21.3 vs. 74.8 ± 22.2; p = 0.004). CONCLUSION: In a real-world setting, primary prevention ICD patients with heart failure report an acceptable disease-specific health status at long-term follow-up. Ischemic and nonischemic etiology showed similar health status whereas atrial fibrillation was associated with worse outcome.


Assuntos
Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Insuficiência Cardíaca/terapia , Prevenção Primária , Qualidade de Vida , Inquéritos e Questionários , Adulto , Idoso , Idoso de 80 Anos ou mais , Efeitos Psicossociais da Doença , Estudos Transversais , Feminino , Estado Funcional , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Comportamento Social , Suécia , Avaliação de Sintomas , Fatores de Tempo , Resultado do Tratamento
15.
J Am Heart Assoc ; 10(16): e021144, 2021 08 17.
Artigo em Inglês | MEDLINE | ID: mdl-34387130

RESUMO

Background Optimal management of asymptomatic Brugada syndrome (BrS) with spontaneous type I electrocardiographic pattern is uncertain. Methods and Results We developed an individual-level simulation comprising 2 000 000 average-risk individuals with asymptomatic BrS and spontaneous type I electrocardiographic pattern. We compared (1) observation, (2) electrophysiologic study (EPS)-guided implantable cardioverter-defibrillator (ICD), and (3) upfront ICD, each using either subcutaneous or transvenous ICD, resulting in 6 strategies tested. The primary outcome was quality-adjusted life years (QALYs), with cardiac deaths (arrest or procedural-related) as a secondary outcome. We varied BrS diagnosis age and underlying arrest rate. We assessed cost-effectiveness at $100 000/QALY. Compared with observation, EPS-guided subcutaneous ICD resulted in 0.35 QALY gain/individual and 4130 cardiac deaths avoided/100 000 individuals, and EPS-guided transvenous ICD resulted in 0.26 QALY gain and 3390 cardiac deaths avoided. Compared with observation, upfront ICD reduced cardiac deaths by a greater margin (subcutaneous ICD, 8950; transvenous ICD, 6050), but only subcutaneous ICD improved QALYs (subcutaneous ICD, 0.25 QALY gain; transvenous ICD, 0.01 QALY loss), and complications were higher. ICD-based strategies were more effective at younger ages and higher arrest rates (eg, using subcutaneous devices, upfront ICD was the most effective strategy at ages 20-39.4 years and arrest rates >1.37%/year; EPS-guided ICD was the most effective strategy at ages 39.5-51.3 years and arrest rates 0.47%-1.37%/year, and observation was the most effective strategy at ages >51.3 years and arrest rates <0.47%/year). EPS-guided subcutaneous ICD was cost-effective ($80 508/QALY). Conclusions Device-based approaches (with or without EPS risk stratification) can be more effective than observation among selected patients with asymptomatic BrS. BrS management should be tailored to patient characteristics.


Assuntos
Síndrome de Brugada/terapia , Técnicas de Apoio para a Decisão , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Adulto , Doenças Assintomáticas , Síndrome de Brugada/diagnóstico , Síndrome de Brugada/economia , Síndrome de Brugada/mortalidade , Pesquisa Comparativa da Efetividade , Análise Custo-Benefício , Desfibriladores Implantáveis/economia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/economia , Cardioversão Elétrica/mortalidade , Eletrocardiografia , Custos de Cuidados de Saúde , Humanos , Pessoa de Meia-Idade , Modelos Econômicos , Anos de Vida Ajustados por Qualidade de Vida , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento
17.
BMC Cardiovasc Disord ; 21(1): 268, 2021 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-34058991

RESUMO

BACKGROUND: ICD patients with episodes of nonsustained ventricular tachycardias (NSVT) are at risk of appropriate therapies. However, the relationship between the cycle length (CL) of such NSVTs and the subsequent incidence of appropriate interventions is unknown. METHODS: 416 ICD patients with LVEF < 45% were studied. ICD programming was standardized. NSVT was defined as any VT of 5 or more beats at ≥ 150 bpm occurred in the first 6 months after implantation that terminated spontaneously and was not preceded by any appropriate therapy. The mean follow-up was 41 ± 27 months. RESULTS: We analyzed 2201 NSVTs (mean CL = 323 ms) that occurred in 250 patients; 111 of such episodes were fast (CL ≤ 300 ms). Secondary prevention (HR = 1.7; p < 0.001), number of NSVT episodes (HR = 1.05; 95% CI 1.04-1.07; p < 0.001) and beta-blocker treatment (HR = 0.7; p = 0.04) were independent predictors of appropriate interventions; however, the mean CL of NSVTs was not (p = 0.6). There was a correlation between the mean CL of NSVTs and the CL of the first monomorphic VT: r = 0.88; p < 0.001. This correlation was especially robust in individuals with > 5 NSVTs (r = 0.97; p < 0.001), with an agreement between both values greater than 95%. Patients with any fast NSVT experienced a higher incidence of VF episodes (26%) compared to those without NVSTs (3%) or with only slow NSVTs (7%); p < 0.001. CONCLUSIONS: Unlike the burden, the CL of NSVTs is not a predictor of subsequent appropriate interventions. However, there is a close relationship between the CL of NSVTs and that of arrhythmias that will later lead to appropriate therapies.


Assuntos
Potenciais de Ação , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Sistema de Condução Cardíaco/fisiopatologia , Frequência Cardíaca , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Idoso , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/fisiopatologia
19.
J Am Heart Assoc ; 10(12): e020353, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34096341

RESUMO

Background Amplitude spectral area (AMSA) predicts termination of fibrillation (TOF) with return of spontaneous circulation (ROSC) and survival in adults but has not been studied in pediatric cardiac arrest. We characterized AMSA during pediatric cardiac arrest from a Pediatric Resuscitation Quality Collaborative and hypothesized that AMSA would be associated with TOF and ROSC. Methods and Results Children aged <18 years with cardiac arrest and ventricular fibrillation were studied. AMSA was calculated for 2 seconds before shock and averaged for each subject (AMSA-avg). TOF was defined as termination of ventricular fibrillation 10 seconds after defibrillation to any non-ventricular fibrillation rhythm. ROSC was defined as >20 minutes without chest compressions. Univariate and multivariable logistic regression analyses controlling for weight, current, and illness category were performed. Primary end points were TOF and ROSC. Secondary end points were 24-hour survival and survival to discharge. Between 2015 and 2019, 50 children from 14 hospitals with 111 shocks were identified. In univariate analyses AMSA was not associated with TOF and AMS-Aavg was not associated with ROSC. Multivariable logistic regression showed no association between AMSA and TOF but controlling for defibrillation average current and illness category, there was a trend to significant association between AMSA-avg and ROSC (odds ratio, 1.10 [1.00‒1.22] P=0.058). There was no significant association between AMSA-avg and 24-hour survival or survival to hospital discharge. Conclusions In pediatric patients, AMSA was not associated with TOF, whereas AMSA-avg had a trend to significance for association in ROSC, but not 24-hour survival or survival to hospital discharge. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT02708134.


Assuntos
Eletrocardiografia , Parada Cardíaca/diagnóstico , Fibrilação Ventricular/diagnóstico , Adolescente , Fatores Etários , Canadá , Reanimação Cardiopulmonar , Criança , Pré-Escolar , Desfibriladores , Cardioversão Elétrica/instrumentação , Europa (Continente) , Feminino , Parada Cardíaca/fisiopatologia , Parada Cardíaca/terapia , Mortalidade Hospitalar , Humanos , Lactente , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Retorno da Circulação Espontânea , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Fibrilação Ventricular/fisiopatologia , Fibrilação Ventricular/terapia
20.
J Am Heart Assoc ; 10(12): e019610, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-34056909

RESUMO

Background Recognizing the etiology of sudden cardiac arrest (SCA) has an enormous impact on the management of victims and their immediate families. A significant proportion of SCA survivors with a structurally normal heart are not offered a diagnosis and there is no clear consensus on the type and duration of follow-up. We aimed to assess the utility of a multidisciplinary approach in optimizing diagnosis of cardiac arrest etiology during follow-up. Methods and Results We retrospectively assessed 327 consecutive SCA survivors (mean age 61.9±16.2 years, 80% men) who underwent secondary prevention implantable cardioverter defibrillators between May 2015 and November 2018. The initial diagnosis was recorded at the time of admission and follow-up diagnosis was deduced from subsequent clinic records, investigations, and outcomes of multidisciplinary team meetings. Structural heart disease accounted for 282 (86%) of SCAs. Forty-five (14%) patients had a structurally normal heart and underwent comprehensive testing and follow-up (mean duration 93±52 weeks). On initial evaluation, 14/45 (31%) of these received a diagnosis, rising to 29/45 (64%) with serial reviews during follow-up. Discussion in multidisciplinary team meetings and imaging reassessment accounted for 47% of new diagnoses. No additional diagnoses were made beyond 96 weeks. Nineteen (5.8%) fatalities occurred in the entire cohort, exclusively in patients with structural heart disease. Conclusions Systematic comprehensive testing combined with multidisciplinary expert team review of SCA survivors without structural heart disease improves the yield and time to diagnosis compared with previously published studies. This approach has positive implications in the management of SCA survivors and their families.


Assuntos
Morte Súbita Cardíaca/etiologia , Técnicas de Diagnóstico Cardiovascular , Cardiopatias/diagnóstico , Equipe de Assistência ao Paciente , Adulto , Idoso , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Feminino , Cardiopatias/complicações , Cardiopatias/terapia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Prevenção Secundária , Fatores de Tempo , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...